Skip to main content

ERF Validation error message incorrectly displayed for Measure Type Values

Written by Gemma
Updated over 5 months ago

Issue:

In the ERF > Endpoints, it is acceptable to have Arms which do not report data and where the number of subjects analyzed is "0". When the "Geometric Mean" and "Confidence Interval" values are blank, the following validation error message is incorrectly displayed.

Measure Type Values: The measure type value is not between the low and high values reported by the confidence interval. Amend this data accordingly.

Workaround:

This validation error message can be ignored as EudraCT will not display a validation error message for this data scenario.

Proposed Resolution:

ADO-2255 has been raised to address this issue in a future release.

Affects Version(s):

All versions

Fixed Version: