Skip to main content

EudraCT Results Submission upload error message: Invalid content was found starting with element 'armComparisonGroupId'

Written by Gemma
Updated over 5 months ago

Issue:

When adding an Endpoint Statistical Analysis, if the subject analysis set is selected before reporting group arm, this causes the XML node to be out of order. Upon upload to EudraCT Results, the following upload error message is displayed:

cvc-complex-type.2.4.a: Invalid content was found starting with element 'armComparisonGroupId'. One of '{subjectAnalysisSetComparisonGroupId}' is expected.

Workaround:

  • Recreate the Statistical Analysis and make sure you select the Reporting Group first and then Subject Analysis Set second, OR

  • Reach out to Support and we can fix the Submission XML ordering. The ordering should be as follows:
    <armComparisonGroupId>
    <subjectAnalysisSetComparisonGroupId>

Proposed Resolution:

ADO-57028 has been raised to address this issue in a future Release.

Affects Version(s):

All Disclose versions

Fixed Version:

TBD

Did this answer your question?