Issue:
When an End Point has a Precision/Dispersion type of "Not Applicable" and a single category with a category title, the category ID value is not included in the submission causing a EudraCT upload error.
Example:
The following error will be displayed on EudraCT when attempting to upload the EudraCT submission.
categoryId should be provided for dispersionValue in armReportingGroups/armReportingGroup with id <categoryId> in endPoint titled 'Test Endpoint'
Workaround:
As a workaround, you can send the submission to TrialScope Support and reference ADO-24595 to receive a corrected submission XML.
Alternatively, the category title can be removed from the End Point to resolve the issue.
Proposed Resolution:
ADO-24595 has been opened to address this issue in a future version of Disclose.